IBM 6223 Personal Computer User Manual


 
Error code/symptom FRU/action
166-342-000 System Management: Failed
(RSA BIST indicate failed tests.)
1. Make sure that the latest firmware levels for Remote
Supervisor Adapter II and BIOS are installed.
2. Disconnect all computer and option power cords from the computer,
wait 30 seconds, reconnect, and retry.
3. Remote Supervisor Adapter II.
180-XXX-000 (Diagnostics LED failure)
v Run diagnostic LED test for the failing LED.
180-XXX-001 (Failed Front LED panel test)
v Information LED panel
180-XXX-002 (Failed Diagnostics LED
panel test)
v System board
180-XXX-003 (Failed system board LED
test)
v System board
180-XXX-005 (Failed SCSI Backplane LED
test)
1. SCSI backplane
2. SCSI backplane cable
3. System board
201-XXX-0NN (Failed Memory test, see
“Installing memory modules” on page 41)
1. DIMM Location slots 1-6 where NN = DIMM location.
Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN 4=DIMM 4
NN 5=DIMM 5 NN 6=DIMM 6
2. System board
202-XXX-001 (Failed System Cache test)
1. Microprocessor 1
2. System board
202-XXX-002 (Failed System Cache test)
1. Microprocessor 2
2. System board
206-XXX-000 (Failed Diskette Drive test)
1. Rerun the test with another diskette.
2. Diskette drive cables.
3. Diskette drive.
4. System board.
214-XXX-000 (Failed Diskette Drive test)
1. Rerun the test with another diskette.
2. Cable.
3. Diskette drive.
4. System board.
215-XXX-000 (Failed IDE CD-ROM test)
1. Rerun the test with a different CD.
2. CD-ROM drive cables.
3. CD-ROM drive.
4. System board.
217-198-XXX
(Could not establish drive parameters)
1. Check the cable and termination.
2. SCSI backplane.
3. Hard disk drive.
.
217-XXX-000 (Failed Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
1. Fixed Disk 1
2. System board
217-XXX-001 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
1. Fixed Disk 2
2. System board
Chapter 6. Symptom-to-FRU index 93