IBM 6223 Personal Computer User Manual


 
ServeRAID error codes
In the following error codes, x can be any number or letter.
Note: See “System replaceable units” on page 117 to determine which components should be replaced by a field
service technician.
Error code/symptom FRU/action
1xxx (Microcode checksum error)
1. ServeRAID controller
2xxx (Code DRAM error)
1. Install download jumpers, flash latest level BIOS and
firmware for controller. Remove jumpers.
2. ServeRAID controller.
3000-31xx(Code DRAM error)
1. Install download jumpers, flash latest level BIOS and
firmware for controller. Remove jumpers.
2. ServeRAID controller.
3200 (Code DRAM error)
1. Install download jumpers, flash latest level BIOS code
and firmware for controller. Remove jumpers.
2. ServeRAID controller.
3300 (ServeRAID-5i only)
1. Install ServeRAID-5i controller in an extended PCI
expansion slot. See the documentation that came with
the server for more information.
3E20 (ServeRAID-5i only)
1. Remove the ServeRAID-5i controller from its slot and
install it in the proper PCI option slot.
2. Verify that the ServeRAID-5i controller is supported in
this server.
3. ServeRAID-5i controller.
4. System board.
3E2x
1. Reseat the ServeRAID controller.
2. Flash latest level of BIOS code and firmware for
controller.
3. ServeRAID-5i controller.
4. Integrated RAID controller on serve).
4xxx thru 5xxx (Code DRAM error)
1. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
2. ServeRAID controller.
6xxx (Cache DRAM error)
(ServeRAID-4H only)
1. Reseat daughter card.
2. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
3. ServeRAID controller.
7xxx thru 8xxx (Host/local PCI bus interface error)
1. Flash latest level of BIOS code and firmware for
controller.
2. If ServeRAID-4x controller, replace controller.
3. If ServeRAID-5i controller, integrated RAID controller
on the computer.
Chapter 6. Symptom-to-FRU index 105