Note: See “System replaceable units” on page 117 to determine which components should be replaced by a field
service technician.
Error code/symptom FRU/action
2462
(Video configuration error)
1. Video adapter (if installed)
2. System board.
5962
(IDE CD-ROM drive configuration error)
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
8603
(Pointing-device error)
1. Pointing device
2. System board
00012000
(Machine check architecture error.)
1. Microprocessor
2. System board.
00019502
(Microprocessor 1 failed)
1. Microprocessor
2. System board
00019xxx (Microprocessor x not
functioning)
1. Verify microprocessor x is installed correctly.
2. Microprocessor x.
3. VRM, if installed.
4. System board.
00151200 (Unrecoverable error,
microprocessor x reported IERR)
1. Microprocessor x
2. VRM
3. System board
00180100
(No room for PCI option ROM)
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
00180200
(No more I/O space available for PCI
adapter.)
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
00180300
(No more memory above 1MB for PCI
adapter.)
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
00180400
(No memory below 1 MB for PCI adapter.)
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
00180500
(PCI option ROM checksum error.)
1. PCI adapter.
2. System board.
00180600
(PCI device BIST failure. PCI bridge error.)
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
00180700
(PCI device not responding.)
1. PCI adapter.
2. System board.
Chapter 6. Symptom-to-FRU index 89