IBM 6223 Personal Computer User Manual


 
Note: See “System replaceable units” on page 117 to determine which components should be replaced by a field
service technician.
Error code/symptom FRU/action
9003
1. Flash latest level of BIOS code and firmware for
controller.
2. Confirm that this controller is a supported option for
this system.
3. ServeRAID controller.
4. Integrated RAID controller on the computer).
9xxx thru BZxx (SCSI bus error caused by cables,
termination, defective drives, etc.). Z refers to the specific
channel or channels that cause the error.
1. Follow indications at “POST (ISPR) error procedures”
on page 107. Follow those instructions before
continuing with the next steps listed in this index.
2. SCSI cable.
3. SCSI backplane.
4. Hard disk drive.
5. ServeRAID controller.
EFFE (Firmware code corrupt or download jumpers are in
place)
1. Flash latest level BIOS and firmware for controller;
then, remove jumpers.
2. ServeRAID controller.
FFFF or other code not listed
1. Follow indications at “POST (ISPR) error procedures”
on page 107.
2. SCSI cable.
3. SCSI backplane.
4. Hard disk drive.
5. ServeRAID controller.
106 IntelliStation Z Pro Types 6223 and 6227: Hardware Maintenance Manual and Troubleshooting Guide