Intel S5000XSL Computer Hardware User Manual


 
Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
7Dh Chassis-
specific
Other Units Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A
Power
Gauge
(aggregate
power)
0Bh
Power
Supply 2
System
ACPI
Power
State
82h All System ACPI
Power State
22h
Sensor
Specific
6Fh
S0 / G0
S1
OK As Trig Offset A X
S3
S4
S5 / G2
G3 mechanical
off
Button 84h All Button Sensor
Specific
6Fh
Power button
Reset button
OK As Trig Offset A X
14h
SMI
Timeout
85h All SMI Timeout
F3h
Digital
Discrete
01h – State
asserted
Critical As and De Trig Offset A
03h
I
2
C device not
found
I
2
C device error
detected
Sensor
Failure
86h All Sensor
Failure
F6h
OEM
Sensor
Specific
OK As Trig Offset A X
73h
I
2
C bus timeout
NMI Signal
State
87h All OEM Digital
Discrete
01h – State
asserted
OK – 01h
C0h
03h
SMI Signal
State
88h All OEM
C0h
Digital
Discrete
03h
01h – State
asserted
OK – 01h
IERR Critical
Thermal trip Non-rec
Config error Critical
Proc 1
Status
90h All Processor
07h
Sensor
Specific
6Fh
Presence OK
As and De Trig Offset M X
Revision 1.2
Intel order number: D41763-003
102