Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
Fan 5
Present
64h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 6
Present
65h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 7
Present
66h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 8
Present
67h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 9
Present
68h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 10
Present
69h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Redundancy
regained
OK
Redundancy
lost
Redundancy
degraded
Degraded
Non-red: suff
res from redund
Non-red: suff
from insuff
OK
Non-red:
insufficient
Critical
Fan
Redun-
dancy
6Fh Chassis-
specific
Fan
04h
Generic
0Bh
Redun degrade
from full
Redun degrade
from non-
redundant
OK
As – Trig Offset A X
Presence OK
Failure Critical
Predictive fail Non-Crit
Power
Supply
Status 1
70h Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
A/C lost Critical
As and De – Trig Offset A X
Revision 1.2
Intel order number: D41763-003
100