Intel S5000XSL Computer Hardware User Manual


 
Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Revision 1.2
Intel order number: D41763-003
95
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used in the comment column to describe a sensor:
- A: Auto-rearm
- M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysterisis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED
Standby
Some sensors operate on standby power. These sensors may be accessed and / or
generate events when the main (system) power is off, but AC power is present.