Intel S5000XSL Computer Hardware User Manual


 
Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
13F 6Fh Bus
uncorrectable
error
Degraded
Bus correctable
error
OK PCIe
Link12
ACh Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link12
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
Bus correctable
error
OK PCIe
Link13
ADh Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link13
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
Proc 1
Thermal
Control
C0h All Temperature
01h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog Trig Offset M
Proc 2
Thermal
Control
C1h All Temperature
01h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog Trig Offset M
Proc 1
VRD Over
Temp
C8h All Temperature
01h
Digital
Discrete
05h
01h – Limit
exceeded
Non-Critical As and De Trig Offset M
Proc 2
VRD Over
Temp
C9h All Temperature
01h
Digital
Discrete
05h
01h – Limit
exceeded
Non-Critical As and De Trig Offset M
Proc 1 Vcc D0h All Voltage
02h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A
Proc 2 Vcc D1h All Voltage
02h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A
Proc 1 Vcc
Out-of-
Range
D2h All Voltage
02h
Digital
Discrete
05h
01h – Limit
exceeded
Non-Critical As and De Discrete R, T A
Proc 2
Vcc Out-
of-Range
D3h All Voltage
02h
Digital
Discrete
05h
01h – Limit
exceeded
Non-Critical As and De Discrete R, T A
Revision 1.2
Intel order number: D41763-003
105