Intel SR9000MK4U Server User Manual


 
42 Intel
®
Server System SR9000MK4U Product Guide
Hot-swapping a Hard Drive
Note: Remove only the failed drive. Removing the wrong drive could cause the system to
malfunction or may cause data loss.
1. Use the LED indicators at the top of the hard drive carriers to determine which
drive has failed. The red LED indicates the failed hard drive. See letter “A” in the
figure below.
Figure 30. Hard Drive LED Indicators
2. Install the new hard drive. See “Installing a Hard Drive” on page 38.
Installing and Removing a Memory Box
Your system was shipped with two memory boxes installed and two memory box filler
panels installed. Before you can use your server system, each memory box must be
populated with either four or eight DIMMs.
Note: The system will not boot if a memory box is installed with no DIMMs in it.
You will need to remove the memory box to perform the following operations:
To replace a memory box
To install or remove DIMMs
To install or remove the mounting plate
AF001115
A