Intel STL2 Server User Manual


 
Server Management STL2 Server Board TPS
3-24
Monitors the event receiver
Controls secure mode, inlucluding video blanding, diskett write-protect monitoring, and
fornt panel lock/unlock initiation
Controls Wake-on-Lan via Magic Packet* support
3.2 Hardware Sensors
The following table lists the hardware sensors present on the STL2 server board.
Sensor Number Sensor Type Monitoring Device
01h Temperature ADM1024 Temperature
02h Processor 1 internal
03h Processor 2 internal
20h Voltage 3.3V
21h 5V
22h 12V
23h 3.3V Standby
24h Processor 1
25h Processor 2
29h 1.5V
2Ah 2.5V
2Ch SCSI-A 2.85V
2Dh SCSI-B 2.85V
2Eh SCSI-A Vref1
2Fh SCSI-A Vref2
30h SCSI-A Vref3
31h SCSI-B Vref1
32h SCSI-B Vref2
33h SCSI-B Vref3
34h Voltage (Discrete) Performance Lags
40h Fan Baseboard Fan 1
41h Baseboard Fan 2
42h Baseboard Fan 3
60h Processor Processor 1 State
61h Processor 2 State
70h Power Distribution Board Soft Power Control Failure (bit 5) Interlock Power
71h Power Distribution Board Supply 1 Power supply Failure detected (bit 1)
72h Power Distribution Board Supply 2 Power supply Failure detected (bit 1)
7Fh Power Redundancy Lost Redundancy Lost (bit 1)
Redundancy Regained (bit 0)
90h Chassis Intrusion ID Drive Bay Intrusion (bit 1)
LAN Leash Lost (bit 4)
91h Security Violation Secure Mode Violation Attempt (bit 0)
92h Memory Error ECC multiple bit error (bit 1)
ECC single bit error (bit 0)
93h POST Memory Resize