Intel STL2 Server User Manual


 
STL2 Server Board TPS Basic Input Output System (BIOS)
Revision 1.0 4-53
Code Error Message Failure Description
0230: System RAM Failed at offset System RAM error
Offset address
0231: Shadow RAM Failed at offset Shadow RAM Failed
Offset address
0232: Extend RAM Failed at address line Extended RAM failed
Offset address
0233: Memory type mixing detected Memory type mixing detected
0234: Single – bit ECC error Memory 1 bit error detected
0235: Multiple- bit ECC error Memory multiple-bit error detected
0250: System battery is dead – Replace and run SETUP NVRAM battery dead
0251: System CMOS checksum bad – Default configuration
used
CMOS checksum error
0252: Password checksum bad - Passwords cleared
0260: System timer error System timer error
0270: Real time clock error RTC error
0271: Check date and time setting RTC time setting error
02B0: Diskette drive A error
02B2: Incorrect Drive A type – run SETUP Incorrect Drive A type
02D0: System cache error – Cache disabled CPU cache error
0B00: Rebooted during BIOS boot at Post Code
0B1B: PCI System Error on Bus/Device/Function PCI system error in Bus/device/Function
0B1C: PCI Parity Error in Bus/Device/Function PCI system error in Bus/device/Function
0B50: CPU#1 with error taken offline Failed CPU#1 because an error was detected
0B51: CPU#2 with error taken offline Failed CPU#2 because an error was detected
0B5F: Forced to use CPU with error An error detected in the entire CPU
0B60: DIMM group #1 has been disabled Memory error, memory group #1 failed
0B61: DIMM group #2 has been disabled Memory error, memory group #2 failed
0B62: DIMM group #3 has been disabled Memory error, memory group #3 failed
0B63: DIMM group #4 has been disabled Memory error, memory group #4 failed
0B6F: DIMM group with error is enabled An error detected in all the memory
0B70: The error occurred during temperature sensor reading Error while detecting a temperature failure.
0B71: System temperature out of the range Temperature error detected.
0B74: The error occurred during voltage sensor reading Error while detecting voltage
0B75: System voltage out of the range System voltage error
0B7C: The error occurred during redundant power module
confirmation
The error occurred while retrieving the power
information
0B80: BMC Memory Test Failed BMC device (chip) failed
0B81: BMC Firmware Code Area CRC check failed
0B82: BMC core Hardware failure
0B83: BMC IBF or OBF check failed Access to BMC address failed
0B90: BMC Platform Information Area corrupted. BMC device(chip) failed
0B91: BMC update firmware corrupted.
0B92: Internal Use Area of BMC FRU corrupted. SROM storing chassis information failed
(Available for use except for FRU command
and EMP function)