![](http://pdfasset.owneriq.net/a/41/a4191b73-a3d4-4fdf-90cf-ae4f07f2ae2f/a4191b73-a3d4-4fdf-90cf-ae4f07f2ae2f-bg6d.png)
■
Duplex LC connector (Rx and Tx)
■
Optical interface support—See Table 36 on page 110
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid
links, take the PIC offline until you are ready to establish a link to another device. For
information about taking a PIC offline, see the request chassis pic offline command in the
JUNOS System Basics and Services Command Reference.
Cables and connectors
One tricolor LED per port:
■
Off—Not enabled
■
Green—Online with no alarms or failures
■
Amber—Online with alarms for remote failures
■
Red—Active with a local alarm; router has detected a failure
LEDs
SONET/SDH OC192c/STM64 PIC with XFP ■ 109
SONET/SDH OC192c/STM64 PIC with XFP