Lenovo 3823 Server User Manual


 
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The Processor CPU nStatus has
Failed with FRB1/BIST condition.
(n = microprocessor number)
Error A processor failed -
FRB1/BIST condition has
occurred.
1. Check for a server firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
2. Make sure that the installed
microprocessors are
compatible with each other
(see “Installing a
microprocessor and heat sink”
on page 220 for information
about microprocessor
requirements).
3. (Trained service technician
only) Reseat microprocessor
n.
4. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
The Processor CPU nStatus has a
Configuration Mismatch.
(n = microprocessor number)
Error A processor configuration
mismatch has occurred.
1. Make sure that the installed
microprocessors are
compatible with each other
(see “Installing a
microprocessor and heat sink”
on page 220 for information
about microprocessor
requirements).
2. (Trained service technician
only) Replace the
incompatible microprocessor.
40 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual