Lenovo RD540 Computer Hardware User Manual


 
hard-disk-drive status LEDs” on page 30. If the solid-state drive is faulty, reinstall or replace it until it
is operating correctly.
11. Save the removed dummy hard-disk-drive tray in the event that you later remove the solid-state drive
and need a dummy tray to cover the drive bay.
What to do next:
To work with another piece of hardware, go to the appropriate section.
To congure RAID, go to “Conguring RAID” on page 62.
To complete the installation, go to “Completing the parts replacement” on page 154.
Replacing a 2.5-inch solid-state drive from a 3.5-inch hard-disk-drive bay
Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 67.
This topic provides instructions on how to replace a 2.5-inch solid-state drive from a 3.5-inch hard-disk-drive
bay.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
To replace a 2.5-inch solid-state drive from a 3.5-inch hard-disk-drive bay, do the following:
1. Locate the appropriate hard-disk-drive bay. See “Server components” on page 25.
2. Press the release button 1 to open the handle of the 3.5-inch drive bracket.
ID
Mem
CPU
PSU
Figure90. Opening the handle of the 3.5-inch drive bracket
124 ThinkServer RD540 User Guide and Hardware Maintenance Manual