Lexmark 4069-XXX Printer User Manual


 
Diagnostic Aids 3-17
4069-XXX
If the high capacity output stacker is selected then the following is
displayed:
HC BIN 1
TP=OP, P=OP, F=OP, NF=OP
IP = high capacity output stacker top position sensor
P = high capacity output stacker passthru sensor
F = high capacity output stacker full sensor
NF = high capacity output stacker near full sensor
If the 5-bin mailbox is selected the following is displayed:
<output bin> (output bin displayed on line 1 = output bin 1,
output bin2, output bin3, output bin4 or output bin 5 for the bin
selector)
P1 = 5-bin mailbox first passthru sensor
P2 = 5-bin mailbox second passthru sensor
L = EM, indicates 5-bin x empty
L = NL, bin contains media but the bin is not near full on full
L = NF, indicates bin is near full
L = FL, indicates bin is full
Base Sensor Test
This test is used to determine if the sensors located inside the
printer are working correctly.
The following sensors can be checked:
Toner Optical Sensor
Input Sensor
Output Sensor (Fuser Exit)
Narrow Media Sensor
Front Door Sensor (Upper Front Cover)
To run the Base Sensor Test:
1. Select the Base Sensor Test.
The operator panel displays OP for open and CL for closed.
2. Manually toggle the sensors by hand to verify that each sensor
switches from open to closed.