Mitsumi electronic NZ2GF-ETB Network Card User Manual


 
112
5. Click the button to set the communication route.
The communication route needs to be set so that communications reach the network of the Ethernet
adapter module (Ethernet part). Because Ethernet adapter modules do not have routing parameters, set
the routing parameters of the master station to perform communications.
*1 This IP address is set on "Ethernet" in the configuration tool. ( Page 118, Section 7.3.5 (1))
Item Description
Target Network No.
Set the network No. of the external device side to be communicated with.
In this setting example, set the third octet of the IP address set in "Ethernet" of the Ethernet
adapter module.
Relay Network No.
Set the network No. of the station where communications transmit through to reach the target
network No.
In this setting example, set the network No. set in "CC-Link IE Field Network" of the Ethernet
adapter module.
Relay Station No.
Set the station No. of the station where communications transmit through to reach the target
network No.
In this setting example, set the station No. set in "CC-Link IE Field Network" of the Ethernet
adapter module.
Master station
Station No.1 Station No.2
Network No.1
Network No.
3 Network No.2
Communication route
to the network No.2
Communication route
to the network No.3
Network No.1
192.168.
3.1 192.168.2.1192.168.3.30 192.168.2.30
*1 *1
192.168.1.1
(Automatically assigned)
192.168.1.125
192.168.1.2
(Automatically assigned)
Ethernet
CC-Link
IE Field
Network
IP address