7.3 IP Communications over CC-Link IE Field Network (IP Packet Transfer Function)
7.3.4 Connection to CC-Link IE Field Network
Details on the routing parameters
Refer to the user’s manual for the master/local module used.
When an external device is connected to an Ethernet adapter module
Set the routing parameters so that communications transmit through the master station.
Communications from an Ethernet adapter module automatically transmit through the master station. The communication
routes must be the same for data sending and receiving; therefore, configure the setting so that communications transmit
through the master station.
Proper setting
Improper setting
*1 An IP communication test related error (error code: 4A28
H
) occurs in the IP communication test.
Ex.
A
B
C
External device
(request source device)
External device
(request destination device)
Local station
Master station
Network No.1
Setting for A
Network No.2
Communication routes set using the routing parameters
Communication route automatically set
(from the Ethernet adapter module to the master station)
Network No.3
Target
Network No.
Relay
Network No.
Relay
Station No.
Setting for B Setting for C
The setting is not required
because the Ethernet
adapter module does not
have the routing
parameters.
Set this column to pass communications
through the master station.
Target
Network No.
Relay
Network No.
Relay
Station No.
3
0
2
112
322
Station
No.2
Station
No.1
Station No.0
Ex.
A
B
C
External device
(request source device)
External device
(request destination device)
Local station
Master station
Network No.1
Setting for A
Network No.2
Communication routes set using the routing parameters
Communication route automatically set
(from the Ethernet adapter module to the master station)
Network No.3
Target
Network No.
Relay
Network No.
Relay
Station No.
Setting for B Setting for C
The setting is not required
because the Ethernet
adapter module does not
have the routing
parameters.
Because the communication route for data sending is different
from that for data receiving, an error occurs.
*1
Target
Network No.
Relay
Network No.
Relay
Station No.
3
2
2
112
Station
No.2
Station
No.1
Station No.0