CHAPTER 7 COMMUNICATION OF THE ETHERNET ADAPTER MODULE
7
7.1 SLMP Communication and Cyclic Transmission
7.1.4 Connection to CC-Link IE Field Network
(3) Checking the connection
After setting the parameters for the master station and the Ethernet adapter module, check if data link can be
normally performed between them, by using the CC-Link IE Field Network diagnostics of GX Works2 connected
to the master station.
1. From the menu of GX Works2, activate the CC-Link IE Field Network diagnostics.
[Diagnostics] [CC IE Field Diagnostics]
The following shows the normal condition.
If a mark, such as , , and , is displayed in "Network Status", an error has occurred. Identify
the cause of the error and take corrective action. ( User's manual for the master/local module used)
If an error occurred in the Ethernet adapter module, the dialog box appears as follows.
Ex.