EDS-508 Series User’s Manual Featured Functions
3-4
Password Setting
Setting Descriptions Factory Default
Old Password (Max.
16 Characters)
Type current password when changing
the password
None
New Password (Max.
16 Characters)
Type new password when changing the
password
None
Retype Password
(Max. 16 Characters)
If you type a new password in the
Password field, you will be required to
retype the password in the Retype new
password field before updating the new
password.
None
Accessible IP
Moxa EtherDevice Switches use an IP address-based filtering method to control access to the
EDS.
Accessible IP Settings allows you to add or remove “Legal” remote host IP addresses to prevent
unauthorized access. Access to EtherDevice Switch is controlled by IP address. That is, if a host’s
IP address is in the accessible IP table, then the host will be allowed access to the EtherDevice
Switch. You can allow one of the following cases by setting this parameter
# Only one host of specific IP address can access the NE-4000T
Enter “IP address/255.255.255.255” (e.g., “192.168.1.1/255.255.255.255”)
# Hosts on the specific subnet can access the NE-4000T
Enter “IP address/255.255.255.0” (e.g., “192.168.1.0/255.255.255.0”)
# Any host can access the NE-4000T
Disable this function. Refer to the following table for more configuration examples.
Allowable Hosts Input format
Any host Disable
192.168.1.120 192.168.1.120 / 255.255.255.255
192.168.1.1 to 192.168.1.254 192.168.1.0 / 255.255.255.0
192.168.0.1 to 192.168.255.254 192.168.0.0 / 255.255.0.0
192.168.1.1 to 192.168.1.126 192.168.1.0 / 255.255.255.128
192.168.1.129 to 192.168.1.254 192.168.1.128 / 255.255.255.128