Moxa Technologies EDS-508 Switch User Manual


 
EDS-508 Series User’s Manual Featured Functions
3-48
2. Configuring Email Settings
To configure EDS’s email setup from the Console interface or browser interface, enter your
Mail Server IP/Name (IP address or name), Account Name, Account Password, Retype New
Password, and the email address(es) to which warning messages will be sent.
3. Activate your settings and test email if necessary
After configuring and activating your MOXA EtherDevice Switch’s Event Types and Email
Setup, you can use the Test Email function to see if your e-mail addresses and mail server
address have been properly configured.
Email Alarm Events Settings
Event Types
Event Types can be divided into two basic groups: System Events and Port Events. System
Events are related to the overall function of the Switch, whereas Port Events are related to the
activity of a specific port.
System Event Warning e-mail is sent when…
Switch Cold Start Power is cut off and then reconnected.
Switch Warm Start EDS is rebooted, such as when network parameters
are changed (IP address, netmask, etc.).
Power Transition (On"Off) EDS is powered down.
Power Transition (Off"On) EDS is powered up.
DI1 (On"Off) Digital Input 1 is triggered by on to off transition
DI1 (Off"On) Digital Input 1 is triggered by off to on transition
DI2 (On"Off) Digital Input 2 is triggered by on to off transition
DI2 (Off"On) Digital Input 2 is triggered by off to on transition
Configuration Change Activated Any configuration item is changed.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have
changed their position (applies only to the root of the
tree).
If Master of Turbo Ring has changed or backup path
is activated.
Authentication Failure An incorrect password is entered.