Director
19
Set the Current Date and Time
Director maintains a time-of-day clock which is used to record the time of trafc peak utilization events. Time is based
on the 24-hour clock. The clock must be initialized using the CLI or another management tool.
To change the current date and time:
Enter 1. time hh:mm:ss where hh is hour, mm is minutes, and ss is seconds.
Enter 2. date mm/dd/yyyy where mm is month, dd is day of the month, and yyyy is year.
Example: time 12:20:00
date 06/24/2008
Save and Load Director Congurations
The entire conguration of Director, including port congurations and lters, can be saved to and loaded from les
stored on Director's internal disk drive. When working with these les from within the CLI, specify only a lename (up
to 32 characters long) without an extension. The current conguration is automatically kept in a le named defaultcfg.
This le is automatically loaded at power up or when the system is reset, so your conguration is persistent. However,
you may wish to save copies of various congurations that you use for different purposes. For example, each person
that uses the device can maintain a separate conguration.
TosavetheDirectorconguration:
Enter • save <lename> where <lename> is the name for this conguration. The conguration is saved.
ToloadaDirectorconguration:
Enter • load <lename> where <lename> is the name of a saved conguration. The conguration is loaded.
ToviewalistofallsavedDirectorcongurations:
Enter • list. A list of Director congurations is displayed.
ToviewasavedDirectorconguration:
Enter • show <lename> where <lename> is the name of a saved conguration. The conguration is displayed.