Net Optics Director Switch User Manual


 
Director
46
Command Sub-Command Arguments Example and description
image < 1 | 2 > image 2
Arguments:
Valid values are 1 and 2
Chooses which system image to boot from (see
upgrade command)
show image show
Lists the names of both system images and indicates
which one is running, and which one is selected to
boot from (arrow next to image name)
list list
Shows a list of lenames of saved Director device
congurations (see save command)
load <lename> load my_conguration-1
Arguments:
<lename> is the name of the le to load; a string;
do not include an extension
Loads a previously saved Director conguration (see
save command)
logout logout
Exits the CLI shell (same as exit and quit)
Note: To maintain system security, control is not
returned to the command shell.
module show module show
Lists information about Director hardware modules
including system serial number, DNM types, and
XFPs
passwd
This
command
is only
available
at root
level
passwd
Interactively changes the password of the SSH user
account
ping <address> ping 10.1.1.4
Arguments:
<address> is an IP address
Pings the specied IP address to check for connectivity
port set ports=<portlist>
autoneg=< on | off >
duplex=< full | half >
speed=< 10 | 100 | 1000 >
port set n1.1-n1.3 autoneg=on duplex=full
Arguments:
<portllist> is a portlist
For other arguments, select a value from the
listed choices
For 10/100/100 Copper interface Network and Moni-
tor ports, enables or disables autonegotiation; selects
the duplex mode; and sets the xed speed (10Mbps,
100Mbps, or 1000Mbps) if autonegotiation is off
show port show
Displays the current port status and settings