Utility Commands
540
ProSafe M4100 and M7100 Managed Switches
no logging email
This command disables email alerting.
Format no logging email
Mode
logging email urgent
This command sets the lowest severity level at which log messages are emailed immediately
in a single email message. Specify the severitylevel value as either an integer from 0 to 7 or
symbolically through one of the following keywords: emergency (0), alert (1), critical
(2), error (3), warning (4), notice (5), info (6), or debug (7). Specify none to indicate
that log messages are collected and sent in a batch email at a specified interval.
Default
Format logging email urgent {<severitylevel> | none }
Mode
no logging email urgent
This command resets the urgent severity level to the default value.
Format no logging email urgent
Mode
logging email message-type to-addr
This command configures the email address to which messages are sent. The message
types supported are urgent, non-urgent, and both. For each supported severity level,
multiple email addresses can be configured. The to-email-addr variable is a standard email
address, for example admin@yourcompany.com.
Format logging email message-type {urgent |non-urgent |both}
to-addr <to-email-addr>
Mode
Format logging email [<severitylevel>]
Mode
Global Config
Global Config
Alert (1) and emergency (0) messages are sent immediately
Global Config
Global Config
Global Config