October 2006 Installing the server and connecting the peripheral devices
1002rp Server Hardware Installation 69
3 Record the MAC address on the Configuration Wizard worksheet that is
provided in the Installation and Configuratio
n Task List
(555-7101-210)
.
You need the MAC address to identify the ELAN when running the
Configuration Wizard to configure the CallPilot server.
4 Connect an RJ-45 network cable from the ELAN hub to the ELAN
connector on the server.
Note: The ELAN hub is optional if you use a cross-over network cable to
make a direct point-to-point connection from the server to the switch.
However, if you choose to establish a direct point-to-point ELAN
connection, no other device can connect to the ELAN.
5 At the switch, connect the ELAN network cable to an MAU (Ethernet)
transceiver. Then complete the connection from the transceiver to the
switch.
.
DANGER
Risk of fire hazard
MAU model NTRH9069 is not suitable for installation in
ducts, plenums, or other spaces used for environmental air. Do
not install it above a false ceiling or below a raised floor,
unless it can be confirmed that these spaces are not used to
convey environmental air.