Nortel Networks 1002rp Network Card User Manual


 
Installing the server and connecting the peripheral devices Standard 1.07
78 CallPilot
2 Connect the other end of the DC power cable to the PDU. Use the
supplied clips and screws to secure the plugs.
The following photograph shows the keyed plug of the DC power cable.
This plug connects to the PDU:
Note: If you are not using a Nortel-supplied PDU, have a qualified
electrician connect the cable appropriately to your DC power plant. The
1002rp uses a negative 48 V power supply, therefore the red cable is
negative (-48 V) and the black cable is the ground (GND).
3 Turn on the PDU.
To start the server
1 Press the server power switch to start the server.
2 Observe the Power-On Self Test (POST) and initialization messages on
the monitor.
3 Let the mini-setup sequence run until you are prompted to login to the
operating system.
Note: The system may perform multiple reboots. This is normal.
4 Ensure that the operating system logon window appears on the monitor.
Note: If the logon window does not appear, refer to the 1002rp Server
Maintenance and Diagnostics (555-7101-206) guide for troubleshooting
instructions.