44 Chapter 2 Nortel VPN Router 1750 chassis
NN46110-316 03.01
Mounting the chassis in the equipment rack
Nortel recommends that two people install the chassis in the rack.
To install the VPN Router 1750 in the equipment rack, perform the following
steps:
1 Set the VPN Router 1750 on the rack-mount shelf.
2 Remove the front bezel from the VPN Router 1750 as shown in the following
figure.
3 Use the Phillips screwdriver to turn each of the two screws on the front bezel a
quarter turn counterclockwise.
4 Grip the two handles, and firmly pull the bezel toward you to unsnap it from
the chassis.
The first several times that you remove the front bezel, the bezel can stick
because the ball studs and socket clips are new.
5 Insert one of the supplied panhead screws through the bottom hole on each
side of the shelf into the hole in the rack, and tighten the screws.
Caution: Risk of equipment damage
Do not use the piece with the Nortel logo and the LEDs as a handle.