User’s Guide 45
English
CATEGORY
Electrical power (continued)
Temperature
Humidity
Location Environment
Vibration
Approvals
Life & duty cycle
Service & Reliability
Consumables life
(Approx.)
ITEM
Peak
AC power cable
Operating
Non-operating
Storage
Transit
Operating
Non-operating
Storage
Transit
Incline
Altitude
Impact
Operation
Transport
Printer life
MTBF
MTTR
Toner life
Oil roller
Waste toner box
Image drum
Transfer belt
Fuser
SPECIFICATION
4A
Standard 1.8m IEC cable fitted with UK or European 3-pin power plug
10 – 32°C (Full colour 17 – 27°C)
0 ~ 43°C
-10 ~ 43°C for less than 1year
-29 ~ 50°C less than 1 month
20 ~ 80% at 25°C (50 ~ 70% for full colour)
10 ~ 90% at 26.8°C
10 ~ 90% at 35°C
10 ~ 90% at 40°C
Maximum 1 degree
2500m above sea level
305mm max drop height while the printer is in its box
5~10Hz 0.1mm; 10~14Hz 0.02G; 14~54Hz 0.05mm; 54~200Hz 0.3G
5~10Hz 10.16mm; 10~14Hz 2G; 14~54Hz 0.38mm; 54~200Hz 5G
EN60950, CE:EN55022 class B/EN50082-1
300,000 pages, 5 years; max. 25,000 pages/month, av. 5000 pages/month
5,700 print hours @ 2.3% duty
20 minutes
3000 pages at 5% density
(2000 pages for first toner cartridge with new drum)
10,000 pages
25,000 pages at 5% density
12,000 pages (cont. printing); 7,500 (3 pages/job); 5,000 (1 page/job)
50,000 pages
60,000 pages