Q-Logic 2300 series Network Card User Manual


 
2 – QCP2330/2332
FCode
CF2351102-00 F 2-7
Q
The new connection mode displays. For example:
Calculating NVRAM checksum, please wait...
Current HBA connection mode: 0 - Loop Only
Possible connection mode choices:
0 - Loop Only
1 - Point-to-point only
2 - Loop preferred, otherwise point-to-point
2.4.3
Setting the QCP2330/2332 HBA Loop ID
When the QCP2330/2332 HBA is currently operating in loop mode (through
connection mode 0 or connection mode 2), perform the following steps to view its
loop ID and change it if necessary:
1. To view the loop ID, type the show-adapter-loopid command.
ok show-adapter-loopid
The loop ID displays. For example:
Adapter loopid - 7c
2. If the loop ID is not correct, change it using the set-adapter-loopid command.
For example:
ok 0 set-adapter-loopid
The new loop ID displays. For example:
Adapter loopid - 0
2.4.4
Selecting the Boot Device
Perform the following steps to select a Fibre Channel device that is attached to the
QCP2330/2332 HBA as the boot device:
1. Use the show-devs command to display the device tree for all devices attached
to the machine.
ok show-devs
The device tree displays. The QCP2330/2332 HBAs with FCode are referenced
with QLGC,qla@. For example:
ok show-devs
.
.
/pci@1f,0/pci@1/QLGC,qla@4