RIC-155 Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-7
Management
V.24/RS-232
ASCII terminal via V.24/RS-232 serial DTE port
Ethernet
Telnet, Web browser or RADview via a MNG port
(out-of-band) or DATA port (inband)
Monitoring
STM-1/OC-3c
Optical input signal
Input signal monitoring based on received B2 error
counting
Frame signal
Alarm indication signal (AIS)
Remote detect indication (RDI)
10/100BaseT
Received valid frames
Transmitted valid frames
Alarm Relay
Alarm Types
Major and minor
Connector
DB-9, female
Indicators
PWR (green)
Power
SPEED (green)
LAN speed
LINK/ACT (yellow)
Ethernet link integrity and activity
ALM (red)
Alarm
SIG (green)
Fiber optic or coaxial signal
Power
AC Source
100 to 240 VAC (±10%), 50 to 60 Hz
DC Source
-48 VDC (±10%) or 24 VDC (±10%)
Power Consumption
8.8W
Physical
Height
43 mm / 1.7 in
Width
215 mm / 8.4 in
Depth
206 mm / 8.1 in
Weight
1.7 kg / 3.7 lb
Environment
Temperature
0–50°C / 32–122°F
Humidity
Up to 90%, non–condensing