RIC-155 Installation and Operation Manual Chapter 4 Configuration
Displaying the RIC-155 Status 4-17
Table 4-1. DATA/MNG Port Status Parameters
Parameters Values
Link Status
• Link Up – DATA/MNG link is up
• Link Down – DATA/MNG link is down
Autonegotiation
• Disabled – Autonegotiation is disabled
• Not Finished – Autonegotiation is being currently performed
• Complete – Autonegotiation process is completed
Duplex State
• Full Duplex – Full duplex operation
• Half Duplex – Half duplex operation
Speed State
• 10 Mbps – 10 Mbps LAN speed
• 100 Mbps – 100 Mbps LAN speed
Partner Pause
• Unknown – Autonegotiation process is not completed
• MAC Pause not Implemented – MAC pause is not implemented in the link partner
• MAC Pause Implemented – MAC pause is implemented in the link partner
Line Indication
• Normal – Primary/management link operates properly
• Major – A major alarm is detected on the DATA/MNG link
• Minor – A minor alarm is detected on the DATA/MNG link
Displaying the STM-1/OC-3c Port Status
Status of the STM-1/OC-3c port can be displayed via the Uplink Status menu.
Table 4-2 lists parameters provided in Uplink Port Status screen.
To display the STM-1/OC-3c port status:
• Follow the path: Monitoring > Physical Port Monitoring > Physical Port Status
> Uplink Status.
The Uplink Status screen appears (see Figure 4-20).
RIC-155
Uplink Port Status
Uplink Connector Type >(Two BNC)
Section >(Normal)
Line >(Normal)
Path >(Normal)
Line Indication >(Normal)
ESC-prev.menu; !-main menu; &-exit
Figure 4-20. Uplink Status Screen