RAD Data comm RIC-155 Network Card User Manual


 
Chapter 4 Configuration RIC-155 Installation and Operation Manual
4-24 Additional Tasks
Resetting RIC-155 to Factory Defaults
You can reset RIC-155 to its default settings. Reseting to the defaults does not
affect the master clock setting. In addition, you can reset local RIC-155 without
affecting its management parameters (IP address, mask and default gateway).
To reset RIC-155 to the defaults:
1. Follow the path: Configuration >System Configuration > Factory default.
Factory Default menu is displayed.
2. From the Factory Default menu, perform one the following steps:
Select All to reset all RIC-155 parameters to the default settings.
Select Without Management to reset all parameters, except for IP address,
mask and default gateway values, community names.
RIC-155 displays the following message:
Request to factory default!!! Are you sure? Y/N
3. Type Y to confirm the reset.
RIC-155 performs the requested type of reset.
Resetting RIC-155
You can perform the overall reset of RIC-155.
To reset RIC-155:
1. From the System Configuration menu, select Reset Device.
A confirmation message appears.
2. Type Y to confirm the reset.