3-4 Configuration Alternatives
Parameter Default Value
Flow control Enable
Ethernet mode Full duplex
LAN speed 100 Mbps
Uplink
Frame type SONET
BER threshold Disable
EED threshold
10E
-3
SD threshold
10E
-6
J1 Tx path trace enable Disable
J1 path trace
Physical Failure Forwarding Disable
Bridge
Aging Time 304
Forwarding Mode Filter
Statistics Counted OK only
Multicast & Broadcast Rate
Limit
No Limit
DATA Port PVID 2
DATA Port PVID Priority 0
DATA Port Tag Stripping No
MNG Port PVID 1
MNG Port PVID Priority 0
MNG Port Tag Stripping No
POS Port Egress Unmodified
3.4 Configuration Alternatives
Managing RIC-155 via Terminal Port
RIC-155 includes a V.24/RS-232 asynchronous DTE port, designated CONTROL
and terminated in a 9-pin D-type female connector. The control port continuously
monitors the incoming data stream and immediately responds to any input string
received through this port. The port requires a cross-cable for the ASCII terminal
connection.
The RIC-155 control port can be configured to communicate at the following
rates: 9.6, 19.2, 38.4, 57.6 or 115.2 kbps. When running a terminal control