Scorpion 240 Autoloader Installation Manual A-53
•
Set the “Maximum delay for the Read/Write
command” to 900
6. Press the
RETURN
key. The drive will be installed in the
system database and the appropriate devices created
7. Exit SMIT
Controlling data compression under AIX
After you run SMIT, device files will have been created for
your new tape drive. Typical filenames are listed below:
/dev/rmt0 /dev/rmt0.1 /dev/rmt0.2 /dev/rmt0.3
/dev/rmt0.4/dev/rmt0.5 /dev/rmt0.6 /dev/rmt0.7
If you enter the configuration information specified in step 5 of
the configuration process, devices rmt0, rmt0.1, rmt0.2 and
rmt0.3 will cause the drive to write in compressed mode.
Using devices rmt0.4, rmt0.5, rmt0.6 and rmt0.7 will cause the
drive to write with compression disabled.
Configuration for SCO UNIX
Before using the Scorpion 240 in an SCO UNIX environment,
set the operating-system configuration dip switches as shown
below:
Switch
5
Switch
6
Switch
7
Switch
8
SCO ODT and Open
Server
installation,
using MAKDEV utility
OFF ON ON OFF
SCO UnixWare 7.x
ON ON ON ON
Configuration for LINUX
Before using the Scorpion 240 in a LINUX environment, make
sure the operating-system configuration dip switches are all
set to ON, as shown below:
Switch 5 Switch 6 Switch 7 Switch 8
Setting