3-24
(15) Initial temperature setting for the print heater (PRINT HEATER)
Sets the platen heater temperature.
(Celsius) (Fahrenheiht)
<Parameter (Enter a value)>
- Range: 15 °C to 55 °C
(The heater will be OFF when "**" is set.)
(16) Initial temperature setting for the rear heater (REAR HEATER)
Sets the rear heater temperature.
(Celsius) (Fahrenheiht)
<Parameter (Enter a value)>
- Range: 15 °C to 55 °C
(The heater will be OFF when "**" is set.)
Celsius or Fahrenheiht display will be alternated on the heater panel.
The setting will be reflected at next powering on.
Celsius and Fahrenheiht conversion equation.
F=(9/5) C+ 32
C=(5/9) (F-32)
(17) Color stripe setting (COLOR STRIPE)
Sets ON/OFF of the color stripe print.
<Parameter (Enter a choice)>
- OFF: Does not print the color stripe at the origin point.
- ON: Prints the color stripe print at the origin point.
*The color stripe is printed on the test print regardless of this setting.
#PRINT HEATER
>01 : 104F
#PRINT HEATER
>01 : 40C
#REAR HEATER
>01 : 122F
#REAR HEATER
>01 : 50C
HINT
#COLOR STRIPE
>01 : OFF