Seiko Group IP-6600 Printer User Manual


 
4-2
Temperature Control
The following are three conditions for heater control.
(1) Preset temperature maintaining condition
Function: To heat the paper for reduction of ink dry time,
improvement of ink fixing, and paper winkles
protection.
Status: Status of maintaining the heater temperature at
preset temperature.
Conditions: (1) In case the heater is turned ON on the heater
control panel and the heater ON command
is received from the engine control board.
(2) In case the status is the same as the (1)’s and
the status until the specified delay time after
receiving the heater OFF command.
(3) In case of heater test.
(2) Standby temperature maintaining condition
Function: To shorten time reaching the preset temperature
at print start.
Status: Status of maintaining the heater temperature at the
specified standby temperature (35 °C) for
all heaters.
When the preset temperature is lower than the
specified stand by temperature (35 °C), the printer
maintaines the preset temperature.
Condition: In case of time specified as the standby time after
completion of the preset temperature maintaining
condition.