n=0:SNMPisdisabled.
n=165535
*SNMPSECLVL=n
SelectsthesecuritylevelrequirementsforSNMPcommunica
tions.
n=0:Nosecurityrequired.SNMPv2candSNMPv3
communicationsareallowed.
n=1:Authenticationequivalentto“authNoPriv”settingin
SNMPv3.SNMPv3isrequiredtodoauthentication,
SNMPv2ctransmissionswillbesilentlydiscarded.
n=2:Authenticationandencryption,equivalentto
“authPriv”ʹsettinginSNMPv3.SNMPv3isrequiredtodo
authenticationandencryption,SNMPv2candSNMPv3
authNoPrivtransmissionswillbesilentlydiscarded.
Messagesarebothauthenticatedandencryptedtoprevent
ahackerfromviewingitscontents.
*SNMPTRAPDEST=host/[port]
ControlsdestinationforSNMPTrapmessages.Ifportis0or
hostisempty,trapsaredisabled.Trapsaresentoutaccording
totheSNMPsecuritylevel(i.e.ifthesecuritylevelis2,traps
willbeauthenticatedandencrypted).Currently,theonlytrap
thatcanbegeneratedislinkup.
host=IPaddress
port=TCPport
*SNTP=n
EnablesdailySNTPupdateofthesystemtime.
n=0:Off
n=1:On
*SNTPADDR=[d.d.d.d][name]
SNTPServerIPaddress,orfullyqualifieddomainname, to
useif*SNTP=1.Ifblank,time.nist.govisused.
d.d.d.d=IPaddress
name=domainname
*TELNETTIMEOUT=n
Telnetportinactivitytimeout.Bydefault,thisvalueissetto
closetheATtelnetconnectionifnodataisreceivedfor2
minutes.
n=minutes