Raven EDGE
103 20070914
Figure 1-12: AceManager : Telemetry
IPL=n
IPListDialallowsaccesstheModbusIPlistusingthefirsttwo
digitsofthedialstring.
Example:ATDT1234567wouldgotoID“12”ontheModbus
listandusetheassociatedIPasthedestination.
• n=0:Disabled
• n=1:Enabled
MVLEN=n
ModbusVariantIDLength:LengthoftheRTUIDina
modbus‐variantprotocol,inbytes.
• n=1:Thisparameterisusedtodefinethelengthofthe
RTUIDinModbus‐likeprotocoldatapackets.
• n=2:ThisparameterisusedwhenthewhentheMDisset
tohex63.
MVMSK=hh
ModbusVariantIDMask:Bytehexmasktousewhen
extractingtheID.SpecifywhichbitsintheIDfieldtouse.This
parameterisusedwhenthewhentheModeDefault(MD)is
settohex63.
• hh=hexvalue
· 00‐nomask,all8bits(default)
· 0F‐onlytheloworder4bits
MVOFF=n
Modbus(variablemode)Offset:Indicatestheoffsetinthedata
ofwheretheModbusIDstarts.
• n=0‐255