Sierra Raven EDGE Network Card User Manual


 
Circuit Switch Communications
Rev 3.0B Feb.08 116
13. Test the Raven Configuration.
Oncethemodemhasbeenactivatedandyou’vebuiltthe
commandstringitisrecommendedthattheRavenmodembe
testedprevioustofieldinstallation.
a. VerifythatthemodemChan,LinkandRegindicators
areblinkinginunisonconfirmingthatthemodemis
nowoperatingincircuitswitched(IS95)mode.
Note: The dial test should be
completed with the serial cable
disconnected to verify that no
signaling is required by the
modem.
b. DialtheRavenmodemtelephonenumberfromaland
lineandverifythatthemodemautomatically answers
thecallwithmodemtones.
c. Verifyoutgoingcalls.
1. Connectthemodemtoyourcomputerwitha
serialcable.Usingaterminalemulationprogram
(HyperTerminal)setupfor9600bps,8databits,no
parityand1stopbit.
2. Enterthecommand:ATD[phone number].Forthe
[phonenumber],enteraknownphonenumber
includingtheareacodeforwhichyoucan hear
ring(suchasyourofficephone).
14. Commission the Raven Modem on
Site.
Thefollowingstepsrepresentaguidelineandmakesassump
tionsthatthemodemhasbeenverifiedpreviouslyina
controlledenvironment.
a. InstalltheRavenmodemverifyingthatallpowerand
antennacablesarecorrectlysecured.
b. VerifythattheRavenmodempowersupandthatthe
Chan,LinkandReglightsblinkinunison.
c. ConnecttheRavenmodemtothelaptopcomputervia
astraightthroughRS232cableorconnecttheserial
cablefromthemodemtoaUSBtoserialdevicethat
hasbeenpreviouslyinstalledonthelaptop.
d. RemovetheconnectiontotheLaptopPCandconnect
yourequipmenttotheRavenModem.
e. Havetheactualapplicationcallyourequipmentvia
themodemtelephonenumberandverifycommunica
tions.