Instruction Manual
97
The following command will synchronize the live system with the new
configuration.
#/bin/cong–-run=ipcong
Dial-in Configuration
To enable dial-in access on the DB9 serial port from the command line
with the following attributes:
Local IP Address: 172.24.1.1
Remote IP Address: 172.24.1.2
Authentication Type: MSCHAPv2
Serial Port Baud Rate: 115200
Serial Port Flow Control: Hardware
Custom Modem Initialization: ATQ0V1H0
You would need to issue the following commands from the command line
to set system configuration:
#/bin/cong–-set=cong.console.ppp.localip=172.24.1.1
#/bin/cong–-set=cong.console.ppp.remoteip=172.24.1.2
#/bin/cong–-set=cong.console.ppp.auth=MSCHAPv2
#/bin/cong–-set=cong.console.ppp.enabled=on
#/bin/cong–-set=cong.console.speed=115200
#/bin/cong–-set=cong.console.ow=Hardware
#/bin/cong–-set=cong.console.initstring=ATQ0V1H0
The following command will synchronize the live system with the new
configuration.
#/bin/cong–-run=dial-in
Please note that supported authentication types are ‘None’, ‘PAP’,
‘CHAP’ and ‘MSCHAPv2’.
Supported serial port baud-rates are ‘9600’, ‘19200’, ‘38400’, ‘57600’,