StarTech.com ECS0016 Server User Manual


 
Instruction Manual
70
Configuring Serial Port Power Strips
The Administrator can configure serially connected power strips, so both
Users and Administrators can control them directly using the Manage-
ment Console. First, the selected gateway serial port must be connected
to and configured to communicate with the power strip:
Connect the power strip to the selected serial port on the ECS0016 1.
gateway
Select the 2. Serial and Network: Serial menu option and configure the
Common Settings of the selected gateway serial port that will be
connected to the power strip with the RS232 properties etc required by
the power strip.
Select 3. Power Strip Mode, then select the Power Device Type to be
controlled.
To simplify power management, you also can also optionally apply 4.
a text label to each of the power outlets on the power strip you have
installed
Enter the 5. Username and Password for accessing the Power Device.
Click 6. Apply.
Configuring IPMI Power Management
The ECS0016 provides power management of servers, storage and telco
devices built with embedded IPMI service processors and BMCs. The
Administrator can configure these IPMI devices, so both Users and Ad-
ministrators can use the Management Console to remotely cycle power
and reboot, even when the operating system is unresponsive.
To set up networked server for IPMI power control, the Administrator must
configure the embedded IPMI device to communicate:
Select 1. Serial & Network: Network Hosts and enter the IP Address/
Domain Name of the BMC or Service Processor (e.g. Dell DRAC)
Then in 2. Power Device Settings, specify the IPMI Power Device Type
(1.5 or 2.0) and Username / Password.
Click 3. Apply