Instruction Manual
27
Network IP Address: 204.15.5.128
Subnet Mask: 255.255.255.224
Click 6. Apply.
The above Trusted Networks will limit access by Users and the Adminis-
trator, to the ECS0016 serial ports and network attached hosts, however
they do not restrict access by the Administrator to the ECS0016 console
server itself. To change the default settings for this access, you will need
to edit the IP tables rules (as described in the Advanced section).
Serial Port Cascading
Cascaded Ports enables you to cluster distributed console servers so a
large number of serial ports (up to 1000) can be configured and accessed
through one IP address and managed through the one Management Con-
sole. One console server, the Master, controls other console servers as
Slave units and all the serial ports on the Slave units appear as if they are
part of the Master.
ECS0016 clustering connects each Slave to the Master with an SSH con-
nection. This is done using public key authentication so the Master can
access each Slave using the SSH key pair (rather than using passwords).
This ensures secure authenticated communications between Master and
Slaves enabling the Slave console server units to be distributed locally on
a LAN or remotely around the world.
To set up public key authentication you must first upload your RSA or
DSA key pair into the Master console server. Please note: If you do not
already have RSA or DSA key pair you will need to create a key pair us-
ing ssh keygen, PuTTYgen or a similar tool as detailed in xxxxxxxxxx
Select 1. System: Administration on Master’s Management Console
Browse to the location you have stored RSA (or DSA) Public Key and 2.
upload it to SSH RSA (DSA) Public Key
Browse to the stored RSA (or DSA) Private Key and upload it to SSH 3.
RSA (DSA) Private Key
Click 4. Apply