Sun Microsystems V890 Server User Manual


 
Maintenance
106 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
8. Using your thumb and forefinger, push the drive latch upward to release the drive handles
for the disks in slots 0 and 3. Swing the handle away from the drive until you feel the drive
connector disengage from the backplane. Do not use excessive force. See the following
figure.
9. Holding the drive by the handle, carefully slide it out of the drive bay.
10. Place the drive on an antistatic mat or in an antistatic bag.
11. Release the drive handle on the replacement disk drive. Use your thumb and forefinger to
pinch the drive latch upward to open it.
12. Align the disk drive with its drive bay. Orient the drive so that the drive handle hinge faces
the bottom of the drive bay.