Sun Microsystems V890 Server User Manual


 
Maintaining disk drives
Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
99
Replacing a single boot disk or replacing data disks
If you are replacing a single boot disk or a data disk, you can hot-plug the disk drives without
shutting down the system.
To remove and replace a single boot disk or a data disk:
1. Unlock and open the front door.
2. Identify which disk drives must be replaced.
3. Enter the following commands:
cd /
luxadm probe
The name of the fiber channel loop is displayed.
4. Record the name of the fiber channel loop. In this example, the name is FCloop.
5. Enter:
luxadm display loop_name
where loop_name is the name of the fiber channel loop.
Example:
luxadm display FCloop
The slot number for every disk in the system is displayed.
Found Enclosure:
SUNWGS INT FCBPL Name:FCloop Node WWN:508002000016b5b0 Logical Path:/dev/es/ses0