Installation
22 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
Required tools
You need the following tools to do the installation:
● Phillips #2 screwdriver
● ESD grounding wrist strap
● Antistatic mat
Electrical specifications
Parameter Value
V880 V890
Input
● Nominal voltage range
● Maximum current AC RMS
● AC operating range
● Nominal frequencies
● 100-240 V AC,
autoranging
● 15.0 A @100 VAC
● 90-264 V rms, 47-63Hz
● 50 Hz or 60 Hz
● 200-240 V AC,
autoranging
● 8.0 A @200 VAC
● 180-264 V rms, 47-63Hz
● 50 Hz or 60 Hz
Maximum DC power output 2240 W 2509 W
Maximum system AC power
consumption
3000 W 3200 W
Maximum system heat dissipation 10308 BTU/hr 10912 BTU/hr
Volt-ampere rating 1515 VA with 1120 Watt load
(PF=0.99)
2078 VA with 1629 Watt load
(PF=0.98)
Wall plug type
● United States
● Non-United States
● NEMA 5-15P
● Power cords must be
obtained locally
● NEMA 6-15P
● Power cords must be
obtained locally
CPU plug type IEC 320 IEC 320