Sun Microsystems V890 Server User Manual


 
Installation
42 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
6. Press and release the power button to the left of the key switch to turn on the system.
Note:
Note: The POST diagnostics occur each time that you turn on the system. The POST
diagnostics test the basic system components and can take several minutes.
While the system turns on, the power LED on the monitor flashes.
7. Press Stop+A simultaneously as soon as the monitor power LED lights steadily and the
Sun logo is displayed on the monitor.
The ok prompt is displayed.
8. Enter the following commands:
setenv auto-boot? false
reset-all
The system resets to the ok prompt.
9. Enter:
probe-scsi-all
This command verifies that the system sees the disk drives and backplane, the tape drive,
and the DVD drive (SCSI model in V880). A message that is similar to the following
example is displayed:
10. Verify that all the devices are recognized. If the devices are not recognized, see
Troubleshooting disk drives and DVD drives
on page 186 for more information.
/pci@8,600000/SUNW,qlc@2
LiD HA LUN --- Port WWN --- -----Disk description -----
0 0 0 21000004cf72f08f SEAGATE ST373405FSUN3660438
1 1 0 21000004cf721553 SEAGATE ST373405FSUN3660438
6 6 0 508002000016b5b1 SUNW SUNWGS INT FCBPL9224
3 3 0 21000004cf72114b SEAGATE ST373405FSUN3660438
4 4 0 21000004cf7211ae SEAGATE ST373405FSUN3660438
/pci@8,700000/scsi@1
Target 5
Unit 0 Removeable Tape HP C7438A V309
Target 6
Unit 0 Removeable Read Only device TOSHIBA DVD-ROM SD-M14011009
/pci@8,700000/pci@5/SUNW,1sptwo@4