Loadable Firmware/Character Generators Length of the Transfer
T5023/5023+ - Programming Guide 289
Reading E-Journal Data
Function:
This command is used to inform the bootstrap loader that the data of the
electronic journal function should be copied from the memory module to the
electronics. This function is reserved for service calls when it is no longer
possible to print data.
The response has the following structure:
ESC
27
1B
E
69
45
L
77
4C
J
75
4A
ASCII chars
Decimal
Hexadecimal
Offset Length Contents Meaning
0 3 E L J Identifier
4max.
128 KB
ASCII Journal contents, code range 20..FE + CR, LF
0 ... 128 KB
END 1 EOF EOF (1A hex)