Tektronix 070-9180-01 Computer Hardware User Manual


 
Command Descriptions
Option 01 VXI Interface Module User Manual
3–27
N/A
[ROUTe:]CONFigure:JOIN
[ROUTE:]CONFigure
[ROUTe:]CLOSe:MODE
Disconnect the commons of all sections of a scanner module. This command is
supported for VX4330, VX4372, and VX4374 Modules.
In these examples the Option 01 is installed on a VX4330 Module. Two addi-
tional VX4330 Modules are installed in consecutive slots to the right of this
module. A VX4374 is installed in the slot to the right of the third VX4330.
Command Response
route:configure:
disjoin m1
Disconnect the commons of the first VX4330.
rout:conf:disj m4 Disconnect the commons of the two sections of the VX4374.
[ROUTe:]CONFigure
:JOIN <module_name>,<section_list>
N/A
All sections on all scanner modules are disjoined.
This command is supported for VX4330, VX4374, and VX4372 Modules. The
section numbers specified in the <section_list> argument must be between 1 and
6 for VX4330 modules. Section numbers 1 and 2 are valid for VX4374 and
VX4372 Modules.
[ROUTe:]CONFigure:DISJoin,
[ROUTE:]CONFigure,
[ROUTe:]MODE
This command connects the commons of adjacent sections on scanner modules.
On VX4330 modules, if a section that is configured as a 4-wire scanner is joined
to a section that is configured as a 1-wire or 2-wire scanner, only the lower half
of the 4-wire scan common is connected. If a 4-wire section is joined to another
4-wire section, both halves of the 4-wire scan common are joined. Also for the
Limits
Related Commands
Description
Examples
Command Syntax
Query Syntax
*RST Value
Limits
Related Commands
Description