SERVICE PROGRAM TABLES April, 2007
5-38
007
PaperInt:2Pt Meas Sets MUSIC to execute with 2-point measurement of
image page intervals.
[0~1/1]
008
JobInt:2Pt Meas Sets MUSIC to execute with 2-point measurements
immediately before image output.
[0~1/1]
010
Interrupt Int Sets the page interval beween MUSIC executions during
long jobs print jobs.
[10~300/1 page]
Note: This SP is effective only when SP2153 005 is
switched ON.
012
MUSIC:Temp Chg Prescribes the exposure unit temperature change at which
MUSIC executes at the start of a job.
[1~300/0.1 deg]
013
MUSIC:2Pt TempChg
Sets MUSIC to execute with 2-point measurement of the
room temperature change.
[1~300/0.1 deg]
014
MUSIC Density Lvl Sets the density of the MUSIC test patterns. Note that the
default is set at the maximum setting.
[0~63/1]
015
Door Open:Wait Sets the time interval for MUSIC to execute after the front
door is opened and then closed to remove a paper jam or
perform some other task.
[2~99/1 min.]
016
Clear Main Slip Clears the skew correction amount for MUSIC in the main
scan direction.
[0~1/1]
020
Sensor Light 1 Sets the light intensity of MUSIC sensor 1.
[0~65535/1]
021
Sensor Light 2 Sets the light intensity of MUSIC sensor 2.
[0~65535/1]
022
Sensor Light 3 Sets the light intensity of MUSIC sensor 3.
[0~65535/1]
023
AutoLight:PreAdj Executes automatic adjustment of the light emitted from
the MUSIC sensors.
[0~1/1]
025
AdjCoeff:FrontKf Sets the value of the coefficient of the front MUSIC
sensor.
[0~100/0.1]
026
AdjCoeff:CtrKc Sets the value of the coefficient for the center MUSIC
sensor.
[0~100/0.1]
027
AdjCoeff:RearKr Sets the value of the coefficient of the center MUSIC
sensor.
[0~100/0.1]
028
Min Patch Fine Sets the minimum amount of patch shift for MUSIC fine
adjustment.
[0~100/0.1]
029
Min Patch:Rough Sets the minimum amount of patch shift for MUSIC rough
adjustment.
[0~100/0.1]