Toshiba e-STUDIO4500c/5500c All in One Printer User Manual


  Open as PDF
of 1120
 
April, 2007 SERVICE PROGRAM TABLES
5-93
3801
Init TD Sensor Execute TD Sensor Initialization
Do this SP after replacing the developer in one or more of the PCUs when servicing
the machine. This SP:
Checks for the presence of developer in the development unit. (This ensures that
the film seal has been removed from the developer pack.)
Initializes TD sensor. (Calibrates Vtcnt).
Calibrates development gamma and calibrates toner density. Also does the
MUSIC check and correction.
Note: Never do TD sensor initializations SP3801 – 001 to 006 after SP3811 – 001
(Developer Set Up). See also the relating pages/chapters 1-32, ch.3.1.6 and
ch.3.5.7.
001
All Colors (Y, M, C, K) [0~1/1]
002
Col (Y, M, C)
003
K
004
M
005
C
006
Y
3802
TD Sn Init OK? Display Result of TD Sensor Initialization
This SP displays the results of the TD sensor initialization with SP3801 001~006.
The machine returns the status of the previous initialization with numbers, 1 digit for
each PCU. The numbers are read in order as "K, M, C, Y".
Four numbers are used to indicate the status of the execution.
1: OK (success)
2: Cancelled (door opened, etc.)
4: Not executed (not selected for execution; this is not an error)
9: Vtcnt abnormal. Vtcnt (TD sensor control voltage) could not be adjusted to within
2.5±0.2V. The machine issued a TD sensor error for the PCU where there is a
problem (SC372~SC375).
3810
ClngInitSetExe Initial Cleaning After Replacement
These SPs should be executed after replacement of the drum cleaning roller or
cleaning blade.
001 All Colors
002 Col Excludes K (Black)
003 K
004 M
005 C
006 Y
Allows adjusment of colors separately.