Toshiba L20 Laptop User Manual


 
2.5 2.5-inch HDD 2 Troubleshooting
Procedure 4 Test Program Check
Run the HDD test program stored on the maintenance test program disk for all test items.
See Chapter 3 for details on how to use the test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and their status names are listed in Table 2-1. If an error code is not generated
and the problem still exists, go to Procedure 5.
Table 2- 1 HDD error code and status
Code
Status
1
Get Parameter Fail !
2
Read Old Data
Error
3
Write Pattern
Error
4
Read Back Data
Error
5 Data Compare Erro
r
6
Restore Data
Error
7 Read Verify Erro
r
9
Seek Erro
r
10 Disk Controller Self Test Failed
11
Disk Controller Test unexpected interrupt Failed
12
Disk Controller action Test Failed
13
Disk dos not support
SMART
14
Disk read attribute threshold
error
15 Disk read attribute value erro
r
16 Disk SMART attribute value erro
r
EQUIUM M40/M45/Satellite M40/M45 Maintenance Manual 2-13